Extech Power Quality Meter PQ3350
Power Quality Meter PQ3350
Benefits
Features
- Two models to choose from : Model PQ3350-1 (1200A 12 INC flexible current clamp probes), Model PQ3350-3 (3000A 24 INC flexible current clamp probes) 
 
- Flexible clamp probes can be used for wrapping around bus bars and wire bundles 
 
- Large back lighting LCD displays up to 35 parameters in one screen 
 
- Clamp-on True RMS power measurements with on-screen Harmonics display 
 
- Simultaneous displayof Harmonics and Wave form < li>
Display of Waveform with Peak Values (1024 samples/period)  
- Analysis of Total Harmon ic Distortion (THD-F) 
 
- Maximum Demand (MDkW , MW, kVA, MVA) with programmable period 
 
- Adj ustable CT ratio (1 to 3000) and VT ratio (1 to 600) 
 
- Graphic Phase diagram with 3-Phase system parameters 
 
- 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor(d0%,d2%) 
 
- Calculated Unbalanced Current through Neutral Line(In) 
 
- Capture 28 Transient events (including Dip, Swell and Outage )with programmable threshold (%) 
 
- Optica lly isolated USB interface with software to download Wave forms, Power P arameters and Harmonics
 
Specifications
- Type : Power Quality Meter
 
- Temp range : None
 
- Rosolution : None
 
- Jaw capacity : Flexible 12 INC
 
- Display : LCD Display
 
- Dc/Ac Current : 1200 A
 
- Capacitance : None
 
- Battery : 8 x AA Battery
 
- Accuracy : +/- 5%
 
- Ac Current : 3000 A
 
- ACV (True rm s) : 600V 
 
- ACCurrent Model : PQ3350-1 (1200A) Resolution : +/-(0.5%rdg+5d) 
 
- PQ3350-3 (3000A) 
 
- Active Power (kW) : 9. 999 MW 
 
- Apparent Power (kVA) : 9999 kVA VA=Vrms x Arms 
 
- Rea ctive Power (kVAR) : 9999 k 
 
- PowerFactor : 0.0 to +1.00 
 
- Fre quency : 45-65Hz 0.1Hz 
 
- Phase : -180.0 - 0 Deg. - (+180.0 +/- 1Deg .) 
 
- Harmonics : 1 to 99 +/-2% 
 
- Crest Factor : 1.00 to 99.99 +/- (5%+30d) 
 
- Peak AC Voltage accuracy : +/-(5%rdg+30d) < li> Peak AC Current accuracy : +/-(5%rdg+30d) 
 
- Active Power Ener gy (kWh) : 0 mWh to 999,999 kWh 
 
- Reactive Power Energy : (kVARh) 0.0kVARh to 1000MWh 
 
- Datalogging : 52428 records (single phase) /17476 records (3 phase) 
 
- Dimensions/Weight : 10.1 x 6.1 x2.3 INC ( 257 x 155 x 57 mm) / 2.5 lbs (1160 Gr)
 
Technical Spec
- Netto Weight 3.000 KG
 
- Unit Dimension 257 X 155 X 57 MM
 
- Height Dimension 57.000
 
- Length Dimension 257.000
 
- Width Dimension 155.000
 
- Type Power Meter
 
- Temperature Ranger None
 
- Lead Time 45
 
- Dimension uom 257.000